Products
- Doorbells[3]
- Circuit Breakers[6]
- Terminal Blocks[6]
- Terminals[6]
- Contactors[6]
- Electrical Plugs & Sockets[6]
- Electronic & Instrument Enclosures[6]
- Fuses[6]
- Other Electrical Equipment[3]
- Power Distribution Equipment[2]
- Switching Power Supply[6]
- Voltage Regulators/Stabilizers[6]
- Relays[6]
- Other Switches[6]
- Push Button Switches[6]
- Remote Control Switches[1]
- Rotary Switches[2]
- Wall Switches[4]
- Power Cords & Extension Cords[1]
- Cable Ties[6]
- Insulation Materials & Elements[1]
- Energy Saving & Fluorescent[3]
- Battery Testers[6]
- Energy Meters[6]
- Voltage Meters[1]
- Alarm[5]
- Traffic Light[6]
- Pliers[6]
Contact Us
- Contact Person : Mr. Lin Kovy
- Company Name : Yueqing KASAN Electric Co., Ltd.
- Tel : 86-577-27880307
- Fax : 86-577-27810608
- Address : Zhejiang,YUEQING CITY,LVAO VILLAGE LIUSHI TOWN YUEQING CITY ZHEJAING CHINA
- Country/Region : China
- Zip : 325604
Product Detailed
Related Categories:Switching Power Supply
Related Product Searches:S-400Swtiching Power Supply,High Quality,Swtiching Power Supply, neon power supply,S-320
1.Universal input voltage
2..10Years Experience Factory
3.2 years warranty
4.12V switching power supply
Related Product Searches:S-400Swtiching Power Supply,High Quality,Swtiching Power Supply, neon power supply,S-320
1. Our company is a professional manufacture and OEM. Our products obtain CE and ISO9001 Certificate and according to IEC 521 international standard to. 2. Low price and high reliability 105 C output capacitor AC input power suitable for the world Hight efficiency and low operation temperature Soft-start current can reduce the AC input impact effecticly With Short-circuit and owwerload protection Compact size, light weight 100% full-load burning test Installed with EMI filter, minimum wave
Model / Specification | SP-400-9 | SP-400-12 | SP-400-13.5 | SP-400-24 | SP-400-48 | |||
DC output voltage | 9V | 12V | 13.5V | 24V | 48V | |||
Output voltage error | ± 1% | ± 1% | ± 1% | ± 1% | ± 1% | |||
Rated output current | 43A | 33A | 29A | 17A | 8.3A | |||
Output current rage | 0-43A | 0-33A | 0-29A | 0-17A | 0-8.3A | |||
Wave and noise | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | |||
Inlet stability | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | |||
Load stability(Note5) | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | ± 0.5% | |||
DC output power | 387W | 396W | 400W | 400W | 400W | |||
Efficiency | 78% | 83% | 85% | 85.5% | 86% | |||
Adjustable range for DC voltage | ± 10% | ± 10% | ± 10% | ± 10% | ± 10% | |||
AC input voltage range | 170~264VAC | |||||||
AC Input current | 5.6A/115V 2.8A/230V | |||||||
AC impulse current | 40A/230V | |||||||
Leakage current | < 3.5mA/240VAC | |||||||
Overload protection | 105%~135% Type : PULSING HICCUP SHUTDOWN Reset: auto recovery | |||||||
Over-voltage protection | 13.8~16.2V | 15.5~18.2V | 18~21V | 27.6~32.4V | 31~36.5V | 57.6~67.2V | ||
Fan control, O. T. P. | RTH3> =60º C~70º C FAN ON, < =55º C~60º C FAN OFF, > =80º C~85º C Cut off output | |||||||
Temperature coefficient | ± 0.03%º C(0~50º C) | |||||||
Setup rise hold up time | 1.5s, 50ms, 20ms | |||||||
Vibration | 10~500Hz, 2G 10min. /1cycle, Period for 60min, EACH AXES | |||||||
Withstand voltage | Input and output interval : 3KVAC, Input and enclosure : 1.5KVAC Output and enclosure : 0.5KVAC | |||||||
Isolation resistance | Input and output interval , Input and enclosure , Output and enclosure : 500VDC/100M Ohms | |||||||
Working temperature and humidity | -10º C~+50º C, 20%~90%RH | |||||||
Store temperature and humidity | -20º C~+85º C, 10%~95%%RH | |||||||
Overall dimension | 241 x 124 x 65mm | |||||||
Weight | 1.2Kgs | |||||||
Safety standards | UL1950, TUV EN60950 | |||||||
EMC standards | EN55022, EN1000-4, 2, 3, 4, 5, 6, 8, 11 IEC100-3-2 | |||||||
Note: 1. The testing condition for the parameter above is: 230VAC input, rated load, 25º C 70%Rh, Humidity2. Error, include the setting error, line stability and load stability. (Note: 5)3. Wave test: adopting“ A12” double wire for 20MHz, and 0.1uF& uF capacitor short-circuit for interrupting4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.5. Load stability test: The load is from 0% to 100%, others 60%.6. C2 , 3, 11must be knocked down. |
S-400Swtiching Power Supply